Portable 1Phase CT Analyzer Test , 19.84 Lbs Current Transformer Tester

  • Origin: China
  • Supply Type: oem service

Supplier Info.

  • Employees Total 201-300
  • Annual Revenue

Portable CT Analyzer

Model: CTP-200P

Portable CT Analyzer CTP-200P is capable of testing Protection CTs, Measuring CTs, TP class CTs and inductive PTs according to IEC61869-2(IEC60044-1,60044-6), IEC61869-3(IEC60044-2), IEEE/ANSI C57.13 etc. test standards. It allows to test the knee-point voltage up to 40kV CTs and PTs on-site in power grids or in manufacturers' production facilities or test labs.

Portable CT Analyzer CTP-200P is an all-in-one solution for measuring all parameters without the need for any further equipment(such as a burden box).

The weight of Portable CT Analyzer CTP-200P is only 9kg(19.84 lbs), which is easy to be carried by testing engineers.

Main Features

●Able to test Protection CTs, Measuring CTs, TP class CTs and inductive PTs

●Test excitation characteristic and error curve based on low-frequency measurement principle

●Measure ratio, polarity, ratio error and se displacement error based on voltage method

●Adopt patented multifunctional rotary mouse to replace the keypad

●Adopt 5.7 inches LCD screen for display

●Adopt DSP, ARM and embedded LINUX operation system

●Both local test and PC remote test available

●Higher measurement accuracy: 0.05 %

●Print test results directly by built-in thermal printer

●Small and light weight (9kg / 19.84 lbs) for easy transport

Technical Data

●Test Standard: IEC61869-2(IEC60044-1,60044-6), IEC61869-3(IEC60044-2), IEEE/ANSI C57.13

●Maximum Knee Voltage Measurement: 40kV

●Output Range:

voltage: 0~180V(RMS)

current: 0~12A(RMS), 36A(peak value)

●Voltage Measurement Accuracy: ±0.05%

●CT Ratio Measurement:

range:1~30000

accuracy: ±0.05%

●PT Ratio Measurement:

range:1~10000

accuracy: ±0.05%

●se Measurement:

accuracy: ±2min

resolution: 0.01min

●Secondary Winding Resistance Measurement:

range: 0~300Ω

accuracy: 0.1%±1mΩ

●Burden Measurement:

range: 0~300VA

accuracy: 0.1%±0.1VA

●Memory Capacity: >3000 groups test results

●Power Supply

Nominal input voltagecustomized (AC230V/120V±10%, 1-se)
Nominal frequency50/60 Hz
Rated current10A at 230V / 12A at 120V
Connectionstandard AC socket (IEC 60320)

●Environmental Conditions

Operation temperature0 ... +50 °C (+32 ... +122 °F)
Storage temperature-25 ... +70 °C (-13 ... +158 °F)
Humidity rangerelative humidity 5 ... 95 %, non-condensing
VibrationIEC 60068-2-6(20m/s2 at 10 ... 150 Hz)

●Misneous

Weight9kg(19.84 lbs)
Dimensions (W x H x D, without handle)340×300×150mm(13.39x11.81x5.91 in)
Connection port2 USB2.0 ports, 1 communication port

Portable CT Analyzer CTP-200P is the powerful tool for testing Current Transformers and Voltage Transformers.