AC Voltage Output 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional)
AC Current Output 200mA, 1A, 5A, 20A, 100A
Frequency Output 45Hz-65Hz
Harmonic 2-51times
Dimensions (W*D*H) (mm) 500*600*175
Weight 27kg

Supplier Info.

  • Company Name GFUVE electronics company
  • Membership:Free
  • Business Type: Manufacturer, Trading Company, Buying Office, Agent, Distributor/Wholesaler, Government ministry/Bureau/Commission, Association, Business Service (Transportation, finance, travel, Ads, etc), Other
  • Employees Total
  • Annual Revenue
  • Â Â GFUVE Kwh Meter Calibration Test Bench GF302D Portable Three se Energy Meter Calibrtaion
  • Able to test basic error, shunt running, start, standard error automatically and manually in single-step of single/three se, according to relative regulation of kWh meter.
  • Able to do change test caused by voltage influence, frequency influence and harmonic influence.
  • Output of power source is speedy and stable, AC maximum output of each se can reach 120A in maximum.
  • Voltage, current and se position of each se can be adjusted in split-se, improving the flexibility of power source.
  • Frequency of each impulse input port can reach 40Hz.
  • 7-inch TFT color display touch screen, English menu, simple and convenient operation, commonly used functions and current basic load point can be controlled in one button.
  • Each meter position can provide one standard, dependent RS485 port, and able to perform multi-function test, such as communication test.
  • Impulse port of each meter position, external polarity can be set randomly, able to adapt kWh meter of impulse cascade and common-anode.
  • Â

    PARAMETERS

    Electrical parametersAC Voltage OutputAC Current OutputPower Output se Output Power FactorFrequency Output Voltage /Current/Harmonic SettingPower Energy Measurement ErrorPower Pulse Output Power Pulse InputMechanical parameters
    Accuracy0.05%, 0.1%
    Power SupplyOne se AC 180-265V, frequency 50/60Hz.
    Range(U1,U2,U3)57.7V, 100V, 220V, 380Vor 69.3V, 120V, 240V, 480V( optional)
    Adjustment range(0-120)%RG(1)
    Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
    Stability0.01%/120s
    Distortion0.3% (Non-capacitive load)
    Output loadeach se 25VA
    Measuring accuracy0.05%RG
    Range(I1,I2,I3)200mA, 1A, 5A, 20A, 100A
    Adjustment range(0-120)%RG
    Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
    Stability<0.01%/120s
    Distortion≤0.3% (Non-capacitive load)
    Output load45VA
    Accuracy0.05%RG
    Active power output stability<0.01%RG/120s
    Reactive power output stability<0.02%RG/120s
    Active power measuring accuracy 0.05%RG
    Reactive power measuring accuracy0.1%RG
    Output adjustment range0°-359.999°
    Output adjustment fineness10, 1, 0.1, 0.01 as optional.
    Resolution0.01°
    Accuracy0.05°
    Adjustment range-1 ~ 0 ~ 1
    Resolution0.0001
    Measurement accuracy0. 0005
    Adjustment range45Hz-65Hz
    Output adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
    Resolution0.001Hz
    Accuracy0.005Hz
    Harmonic /td>2-51times
    Harmonic content0-40%
    Harmonic se0-359.99
    Harmonic setting accuracy(10%±0.1%)RD(2)
    Active power energy0.05%RG
    Reactive power energy0.1%RG
    Power pulse typeactive pulse, reactive pulse
    Active power pulse output 5V, 10mA
    Energy pulse typesupport active and reactive pulse, the highest frequency power pulse input is 180K.
    Dimensions (W×D×H) (mm)500x600x175
    Weight (kg)About 27
    (1) RG means range, the same as below;(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.