Join today and be a part of the fastest growing B2B Network Join Now

DT Pro wireless temperature / humidity / pressure verification system

  • Origin: China
  • Supply Type: in stock
  • Processing Time: 15 days after payment
  • Min Order: 1

Supplier Info.

  • Employees Total 11-50
  • Annual Revenue Below US$1 Million

DT Pro rature / humidity / pressure verification system can be widely used in equipment verification and environmental monitoring in rmaceutical, food, biological, chemical and other industries. Compared with the traditional tion system, the probe can be conveniently and quickly arranged, and the detection point is physical constraints greatly improve verification efficiency.

Function

The system consists of a der (temperature,humidity, pressure), a data reading workstation, and ication software.

The temperature recorder can effectively store 16000 pieces of data, and the temperature measurement accuracy is 0.1 ℃, which fully meets the needs of equipment and process verification in food and drug production enterprises and the verification needs in the fields of bioengineering, medical and transportation. The recorder uses replaceable batteries, with large power, low power consumption and long battery life. Adopt high pressure and waterproof design, can be used continuously for a long time in high pressure and high humidity environment.

The data reading workstation is divided into a single-hole workstation and a 10-hole workstation. The universal USB serial port is used to connect to the computer, and data communication can be carried out conveniently, efficiently and safely.

The software realizes data collection, data analysis and report generation, meets FDA 21 CFR Part 11, and supports electronic signature of documents. Support custom stages and verify each stage to generate stage verification report.

Features:

â—‡ Switch between Chinese and English versions at will;

â—‡ Comply with FDA 21CFRPart 11 regulations;

â—‡ With data audit tracking function, with three levels of authority (freely assignable authority);

â—‡ It has data statistical analysis functions, including large and small values, average value, span, temperature difference at the same time, F0 value test, etc., and can be freely selected according to needs.

Application scenarios:

The system can be applied to GMP rmaceutical industry, GSP industry, biological industry, medical industry, food industry, transportation industry.

GMP

Steam sterilizer verification / water bath sterilizer verification, rubber plug washer verification / aluminum lid washer verification, freeze dryer verification / cryogenic refrigerator verification, constant temperature and humidity chamber verification / stability incubator verification

GSP

Cold storage verification / refrigerated truck verification, refrigerator / incubator verification, cool storage / normal temperature storage verification

Biological

Stirred fermentation tank verification, culture tank verification, process development data

Food

Pasteurization verification, sterilization tunnel verification, rotary freezer verification, blast freezer verification, cold room verification

Transport

Cold chain process tracking, cabin temperature detection

Medical

High temperature sterilization testing, steam sterilization testing, medical supplies testing

Technical Parameters

Â

Temperature Verifier

Temperature and humidity tester

Pressure Verifier

Model

TDL-2

TDL-2-S(Flexible probe)

HDL-1

PDL-1

Operating temperature

-50 ~ 150 ℃(expandable to 400˚C with heat insulation box)

-50 ~ 150 ℃ (expandable to 400˚C with heat insulation box)

-40~125℃

-40~140℃

Range

-50~150℃

-50~150℃

0~100%RH

0~100psi0~6.894Bar(Absolute pressure)

Resolution

0.01℃

0.01℃

0.01℃

0.008psi;

0.01%RH

0.55mBar

Accuracy

±0.1℃

±0.1℃

±0.2℃

±0.25% Full scale

±2%RH

Sensor

Pt100 Class 1/3 DIN

Pt100 Class 1/3 DIN

Temperature: Pt100

Strain

Humidity: capacitive

Capacity (recording points)

64,000

64,000

8,000

8,000

Record frequency

1 second to 18 hours

1 second to 18 hours

1 second to 18 hours

1 second to 18 hours

Battery Life

36 months

36Â months

12Â months

12Â months

Communication method

RS 485 /span>

RS 485Â /span>

RS 485Â /span>

RS 485Â /span>

Â

Premium Services
Get Targeted Quotations
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok