This er provides the galvanic isolation between field circuits and control circuits. The device is used with strain gauges, load and resistance measuring bridges. Designed to provide 5 V excitation voltage, this barrier&rsquo,s high quality A/D converter allows it to be used with those devices requiring 10 V. Up to four 350 ⦠strain gauges connected in parallel may be powered and evaluated. The device is easily configured by the use of keypad or with the PACTware configuration software. The current measurement for tare, zero point, and final value can be entered in this manner. A fault is Ds and a separate collective error message output. For additional information, refer to the manual and .
General specifications
| Analog input |
Supply
Connection | Power Rail or terminals 23+, 24- |
Rated voltage | 20 ... 35 V DC |
Ripple | within the supply tolerance |
Power consumption | max. 3 W |
Interface
Connection | Power Rail or terminals 19+, 20 GND, 21- |
Type | RS-485 |
Programming interface | programming socket |
Field circuit
Connection | terminals 1+, 2-, 3+, 4-, 5+, 6- |
Lead resistance | max. 25 &Omega, per |
Input I | |
| Connection | terminals 1+, 2- |
Sensor supply | 1 ... 5 V |
| Connection | terminals 3+, 4- (supply), 5+, 6- (r> |
| Short-circuit current | 50 mA |
| Load | &ge, 116 &Omega, up to 5V, &ge, 85 &Omega, up to 4V |
Input
Connection side | field side |
Connection | Input I: terminals 1+, 2-, Input II: terminals 13+, 14-, Input III: terminals 15+, 14- |
Programmable Tare | 0 ... 500 % of span |
Input I | td> |
| Input 100 ... 100 mV |
| Input resistance | > 1 M&Omega, for voltage measurement |
Input II, III | tare adjustment, calibration and zero |
| Open circuit voltage/short-circuit current | 18 V / 5 mA |
| Active/Passive | I > 4 mA/I < 1.5 mA |
Output
Connection side | control side |
Connection | Output I: terminals 10, 11, 12, Output II: terminals 16, 17, 18, Output III: terminals 7-, 8+, 9- |
Output I, II | Relay output |
| loading | 253 V AC/2 A/500 VA/cos &, min. 0.7, 40 V DC/2 A resistive load |
| Mechanical life | 2 x 107 switching cycles |
Output III | Analog output |
| Current range | -20 ... 20 mA |
| Load | max. 550 &Omega, |
| Analog voltage output | 0 ... ± 10 V, output resistance 500 &Omega, (bridge between terminal 7 and 9) |
| Analog current output | 0 ... ± 20 mA or 4 ... 20 mA, load 0 ... 550 &Omega, (terminals 7 and 8) |
t detection | downscale -21.5 mA (-10.75 V) or 2 mA (1 V), upscale 21.5 mA (10.75 V) |
Collective error message | Power Rail |
Transfer characteristics
Deviation | |
| Resolution/accuracy | &le, ± 0.05 % incl. non- and hysteresis |
| Temperature effect | &le, ± 0.01 %/K |
Reaction time | 300 ... 850 ms |
Galvanic isolation
Input I/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Output I, II against eachother | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Output I, II/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Output III/Input II, III | not available |
Output III/Programming socket | not available |
Other circuits from each other | functional insulation, rated insulation voltage 50 Veff |
Indicators/settings
Display LEDs , display |
Control Control panel |
Configuration | via operating buttons via PACTware |
Labeling | space for labeling at the front |
Directive conformity
Electromagnetic compatibility | |
| Directive 2004/108/EC | EN 61326-1:2006 |
Low voltage | |
| Directive 2006/95/EC | EN 61010-1:2010 |
Conformity
Electromagnetic compatibility | NE 21:2006 |
Degree of protection | IEC 60529:2001 |
Ambient conditions
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
Degree of protection | IP20 |
Connection | screw terminals |
Mass | approx. 250 g |
Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3 |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
International approvals
UL approval | E223772 |
General information
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see . |