Quick Details
- Processing Time:60days
- Port:Qingdao
- Supply Ability: 100 Sets Per Month
- Brand Name:Goodfood Machinery
Static Steam Retort
Sterilizer/Sterilization Retort/Sterilizing/Autoclave Sterilizer(GF-SS)
Applications:
1. Metal container: tin can;
2. Soft pouch: aluminum-foil pouch, transparent pouch, vacuum pouch, high
temperature retort pouch.
Features:
1. Water from different angles, steam, air and water mixed convection,
forming a perfect temperature distribution;
2. Low noise, create a quiet, comfortable operating environment;
3. Equipped with four movable temperature sensing probe, can be monitored
at any time in the food center of F-measure, the thermal distribution of the kettle, at any time to understand the thermal penetration (temperature from food surface to the food geometric center
of time);
4. Perfect pressure control, the whole production process of the pressure
in constant adjustment, in order to adapt to the changes in the internal pressure of the product packaging, so that the product packaging of the deformation of the lowest, especially suitable for
gas bearing products;
5. The whole sterilization process adopts PLC fully automatic linearity
control. Via the PLC control, the temperature difference of thermal distribution is limited within ±0.2°C. The autoclave sterilizers allow for multi-stage heating, effectively saving energy. It
also has an additional F value recorder (optional), capable of storing 100 scheduled processes.
Technical Parameters:
Model
Unit
700#
900#
1000#
1200#
1300#
Retort chamber length
mm
1200
1800
2200
2400
2400
3200
3600
4000
3600
4500
Overall length
mm
1600
2500
3000
3300
3400
4000
4500
5200
5000
5500
Overall width
mm
1000
1200
1400
1400
1600
1600
1600
1600
1800
1800
Overall height
mm
1500
1600
1600
1600
1800
1800
1800
1800
2000
2000
Effective volume
m³
0.6
1.2
2.0
2.2
3.1
4.0
4.6
5.0
5.3
6.5
Crate
pcs
3
8
12
12
15
20
20
25
24
30
Steam consumption
KG
40
70
105
115
180
230
255
280
300
370
Power
KW
2.8
5.5
5.5
5.5
7.5
7.5
7.5
7.5
7.5
7.5
Design temperature
145℃
Test pressure
0.44Mpa
Design pressure