Quick Details
- Processing Time:-
- Port:-
- Supply Ability: -
- Brand Name:PEPPERL+FUCHS
1-channel signal conditioner
24 V DC supply (Power Rail)
Strain gauge input (full or half bridge)
Output 0 mA ... ± 20 mA or 0 V ... ± 10 V
2 relay contact outputs
Programmable high/low alarm
Configurable by PACTware or keypad
RS-485 interface
Line fault detection (LFD)
This signal conditioner provides the galvanic isolation between field circuits and control circuits. The device is used with strain gauges, load cells and resistance measuring bridges. Designed to
provide 5 V excitation voltage, this barrier&rsquo,s high quality A/D converter allows it to be used with those devices requiring 10 V. Up to four 350 Ω strain gauges connected in parallel may
be powered and evaluated. The device is easily configured by the use of keypad or with the PACTware configuration software. The current measurement for tare, zero point, and final value can be
entered in this manner. A fault is signalized by LEDs and a separate collective error message output. For additional information, refer to the manual and .
Product Description
24 V DC
General specifications
Signal type
Analog input
Supply
Connection
Power Rail or terminals 23+, 24-
Rated voltage
20 ... 35 V DC
Ripple
within the supply tolerance
Power consumption
max. 3 W
Interface
Connection
Power Rail or terminals 19+, 20 GND, 21-
Type
RS-485
Programming interface
programming socket
Field circuit
Connection
terminals 1+, 2-, 3+, 4-, 5+, 6-
Lead resistance
max. 25 &Omega, per line
Input I
Connection
terminals 1+, 2-
Sensor supply
1 ... 5 V
Connection
terminals 3+, 4- (supply), 5+, 6- (signal)
Short-circuit current
50 mA
Load
&ge, 116 &Omega, up to 5V, &ge, 85 &Omega, up to 4V
Input
Connection side
field side
Connection
Input I: terminals 1+, 2-, Input II: terminals 13+, 14-, Input III: terminals 15+, 14-
Programmable Tare
0 ... 500 % of span
Input I
Signal, analog
Input signal
-100 ... 100 mV
Input resistance
> 1 M&Omega, for voltage measurement
Input II, III
tare adjustment, calibration and zero
Open circuit voltage/short-circuit current
18 V / 5 mA
Active/Passive
I > 4 mA/I < 1.5 mA
Output
Connection side
control side
Connection
Output I: terminals 10, 11, 12, Output II: terminals 16, 17, 18, Output III: terminals 7-, 8+, 9-
Output I, II
Relay output
Contact loading
253 V AC/2 A/500 VA/cos &phi, min. 0.7, 40 V DC/2 A resistive load
Mechanical life
2 x 107 switching cycles
Output III
Analog output
Current range
-20 ... 20 mA
Load
max. 550 &Omega,
Analog voltage output
0 ... ± 10 V, output resistance 500 &Omega, (bridge between terminal 7 and 9)
Analog current output
0 ... ± 20 mA or 4 ... 20 mA, load 0 ... 550 &Omega, (terminals 7 and 8)
Line fault detection
downscale -21.5 mA (-10.75 V) or 2 mA (1 V), upscale 21.5 mA (10.75 V)
Collective error message
Power Rail
Transfer characteristics
Deviation
Resolution/accuracy
&le, ± 0.05 % incl. non-linearity and hysteresis
Temperature effect
&le, ± 0.01 %/K
Reaction time
300 ... 850 ms
Galvanic isolation
Input I/other circuits
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachother
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuits
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/Input II, III
not available
Output III/Programming socket
not available
Other circuits from each other
functional insulation, rated insulation voltage 50 Veff
Indicators/settings
Display elements
LEDs , display
Control elements
Control panel
Configuration
via operating buttons via PACTware
Labeling
space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2004/108/EC
EN 61326-1:2006
Low voltage
Directive 2006/95/EC
EN 61010-1:2010
Conformity
Electromagnetic compatibility
NE 21:2006
Degree of protection
IEC 60529:2001
Ambient conditions
Ambient temperature
-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection
IP20
Connection
screw terminals
Mass
approx. 250 g
Dimensions
40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Mounting
on 35 mm DIN mounting rail acc. to EN 60715:2001
International approvals
UL approval
E223772
General information
Supplementary information
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see .