10kVA - 80kVA Three Phase Online High Frequency Smart Power UPS

FOB Price: USD 100 - 100
|
3 Cartons (Min. Order)
  • Supplying Ability50000 Units Per Month
  • Supplying TypeOem service
  • Model Number33Q10K-80K
  • Preferred Payment Method:T/T, L/C, Western Union, Money Gram, PayPal

Quick Details

  • RS232/Snmp:Support
  • Technology:IGBT & Parallel Card
  • Battery:Internal/External
  • Cold Start:Available
  • Processing Time:15- 20 days
  • Port:shenzhen
  • Supply Ability: 50000 Units Per Month
  • Brand Name:UPSEN
10KVA - 80KVA Three Phase Online High Frequency Smart Power UPS High Frequency Online UPS Queen Star Plus Strar Series 33Q10K-80K(3Ph in/3Ph out) Features:  1: The load PFC is 0.8 2: Environment Friendly 3: Support the generator 4: Sufficient Expansion Slots 5: Output transfer time is 0ms 6: Adaptive Load Management 7: Programmable power management outlets  8: Wide range of input voltage and frequency 9: DSP technology guarantees high performance  10: Standard communication options: RS-232 communication port 11: Sixth generation IGBT,much higher efficiency, lowetemperaturer,more reliable 12: Independent ventilation enhance durable operation under harsh environment 13: Excellent input frequency range makes UPS suitable to different power supply devices, i.e. generator set Technical Specification: Index 33Q 10KL 33Q 20KL 33Q 30KL 33Q 40KL  33Q 60KL  33Q 80KL Comments Input Input voltage Rated voltage 380VAC/220VAC 380VAC Phase three phase with ground Turn on  voltage range (120±5~274±5)VAC (207±9~475±9) VAC Bypass  voltage range (60±5~300±5)VAC (105±9~518±9) VAC Could be  adjusted  by software. Bypass  low loss 60VAC~220VAC(default 60VAC) 105VAC~380VAC (default 105VAC) Bypass  low comeback Low loss +5VAC Low loss  +17VAC Bypass  high loss 220VAC~300VAC(default 300VAC) 380VAC~475VAC (default 475VAC) Bypass  high comeback High loss -5VAC High loss -17VAC Line low loss comeback (120±5) VAC /(140±5) VAC (207±9) VAC  (242±9) VAC load≤50% (140±5) VAC /(160±5) VAC (242±9) VAC (276±9) VAC 50%≤90% (160±5) VAC /(175±5) VAC (276±9) VAC (302±9) VAC load>90% Line high loss comeback (275±5)VAC/(260±5)VAC (475±9)VAC (449±9)VAC Input frequency Rated  frequency 50Hz Frequency  low loss (40~49) ±0.2Hz(default:46Hz) Could be  adjusted  by software. Frequency  low comeback Frequency low loss +0.5Hz Frequency  high loss (51~60)±0.2Hz(default:54Hz) Frequency  high comeback Frequency high loss -0.5Hz Input power factor Could be  adjusted  by software. > 0.99 33Q 10-40KL: 220VAC,full R load 33Q 60-80KL:  380VAC,full R load Generator  Support generator input Generator rating ≥2*UPS rating Input current Rated current  14A 28A 42A 67A 80A 105A Input THDI <= 10% Output protection Rating  protection 32A  Breaker 50A  Breaker 60A  Breaker 80A  Breaker 100A  Breaker 125A  Breaker Output power VA/watt 10KVA/8KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 60KVA/ 48KW 80KVA/ 64KW Rated voltage 220VAC 380VAC Sine wave Voltage range 200/208/220 /230/240VAC 345/359/380 /397/415 VAC 33Q 10-40KL:  Could be  adjusted  by software.  10% derating  for  208VAC /200VAC. 33Q 60-80KL:  Could be  adjusted  by software.  10% derating  for 345VAC /359VAC. Voltage regulation ±1% Voltage distortion ≤5% ≤10% Full RCD load ≤3% Full R load DC offset ≤200mV Transient response ≤9% R load  0%~100%~0% ≤6% R load 20% ~100%~20% Transient recovery ≤60ms voltage recovery to 90% Full RCD load Bypass output  before turn-on YES Crest ration 3:1 Output frequency range Normal mode 1,Same as input frequency(46Hz~54Hz) 2,50Hz(Input frequency>54Hz or Input frequency<46Hz) Battery mode (50±0.1) Hz Slew rate 1 Hz/Sec Efficiency Normal  mode > 93% > 90% Battery mode > 90% > 90% Overload Normal mode battery mode  Overload warning only 105%±5%≤load 1min,then transfer to bypass and alarm. 105%±5%< load≤125%±5% 30S,then transfer to bypass and alarm. 125%±5%< load≤150%±5% 300mS, then transfer to bypass and alarm. load>150%±5% Automatically  retransfer YES Short protection Normal battery mode YES Transfer time Normal to  battery mode 0mS Battery to  normal mode 0mS Normal to  bypass mode <4mS 0mS Bypass to  normal mode <4mS 0mS Battery and charger Battery Rated voltage 192VDC 240VDC 192VDC*2 192VDC*2 480VDC Type/Rating Battery  quantity 16 20 16*2 16*2 40 Backup time Protection Low alarm voltage  comeback voltage (180.8V±4V)/ (188.8V±4V) (226V±4V)/ (236V±4V) (180.8V±4V) (188.8V±4V) (226V±4V)/ (236V±4V) (452V±4V) (472V±4V) 33Q 30KL  use two  Shutdown voltage comeback voltage 160V±4V/ 168V±4V (200V±4V)/ (210V±4V) 160V±4V/ 168V±4V (200V±4V)/ (210V±4V) (400V±4V) (420V±4V) DC protection Overcharge  protection comeback voltage (249.6V±4V) (216V±4V) (312V±4V) (270V±4V) (249.6V±4V) (216V±4V) (312V±4V) (270V±4V) (624V±4V)  (540V±4V) Leakage current < 500uA Over  discharge  protection 14.5h Could be  set by software Battery test Battery weak YES Battery fault YES Charger Output voltage (219.2±3)VDC (277±3)VDC (219.2±3)VDC (277±3)VDC (554±3)VDC Charge time Depends on the external battery capacity Charge current 7.5A 6A 5A 4A 10A Interface Alarm silence YES DC power  turn-on YES Automatically  retransfer YES Audio alarm Battery mode Beep/4s Battery low charger fault Beep/1s UPS fault Continue beep Overload Beep/1s Bypass mode Beep/2Min L/N inverse Beep/2Min Communication RS232 interface YES Intelligent slot YES Monitor software Appending with UPS Cooling Force air cooling Display LCD/LED displays UPS status Environment Work  temperature 0ºC~40ºC Altitude <1000m Audible  noise ≤60dB Storage  temperature -15ºC~45ºC Work humidity 20%~95% Standard EMS ESD IEC61000-4-2 Level4 RS IEC61000-4-3 Level3 EFT IEC61000-4-4 Level4 Surge IEC61000-4-5 Level4 EMI Conducted EN55022 Class A Radiated EN55022 Class A Safety Safety GB4943-2001/IEC62040-1 Machinery features Size Outline dimension and net weight L*W*H (mm) 710*260*717 840*515*1135 Net weight(Kg) 45/93 50/98 195 208 Optional functions 60Hz Optional Set by software Converter mode Optional Set by software ECO Optional Optional Available and  set by software EPO Optional Optional LCD display Optional